Skip to content
Chlorinated Solvent · Perkloroetilena for Dry Cleaning, Degreasing & Synthesis

Perchloroethylene (PCE) CAS 127-18-4 Supplier in Indonesia

Cl2C=CCl2 C2Cl4 · 165.82 g/mol · about 85.5% Cl

Chelora Chemicals supplies perchloroethylene, C2Cl4, the clear, colourless, non-flammable chlorinated solvent also known as PCE, PERC or tetrachloroethylene, to industrial buyers across Indonesia. In Bahasa Indonesia it is described as perkloroetilena or tetrakloroetilena, descriptive names rather than fixed trade terms, and the dry-cleaning trade simply calls it perc. It boils at 121 °C, dissolves oils, fats, waxes and resins strongly, and is almost insoluble in water. That makes it the classic solvent for dry cleaning machines, a standard fluid for vapour and cold degreasing of metal parts, a processing solvent in textile mills and a chemical intermediate for fluorocarbons. We supply dry-cleaning and high-purity grades in steel drums, IBCs and ISO tanks, with purity, water, acidity and colour on every certificate of analysis.

CoA with every batchGHS SDS · UN 1897 documentsFOB · CFR · CIF · DAPPengiriman ke seluruh Indonesia
Identification Sheet C2Cl4
ProductPerchloroethylene (PCE)
Chemical nameTetrachloroethylene (1,1,2,2-tetrachloroethene)
CAS number127-18-4
EC number204-825-9
EU index number602-028-00-4
PubChem CID31373
FormulaCl2C=CCl2, also written C2Cl4
Molar mass165.82 g/mol
Boiling pointAbout 121 °C at 101.3 kPa
HS code2903.23 (tetrachloroethylene)
UN numberUN 1897, Class 6.1, PG III
Common synonymsPCE, PERC, perc, tetrachloroethene, ethylene tetrachloride, perkloroetilena
Purity (GC)≥ 99.5%99.9% high-purity grade on request
AppearanceClear, colourless liquidmild sweetish, ether-like odour
Density (20 °C)About 1.62 g/cm3heavier than water
Boiling PointAbout 121 °Cfreezing point about −22 °C
FlammabilityNon-flammableno flash point; breaks down in flame
Grades OfferedDry-Cleaning / High-Puritystabilised; ≥ 99.5% and ≥ 99.9%
01 / PRODUCT DOSSIER

What perchloroethylene is: the non-flammable chlorinated solvent for dry cleaning and degreasing

What the name means, why this solvent became the standard in dry cleaning and vapour degreasing, what stabilisation does, and how Chelora Chemicals supplies it to Indonesian plants.

Perchloroethylene is the fully chlorinated form of ethylene, Cl2C=CCl2, registered as tetrachloroethylene under CAS 127-18-4 and EC 204-825-9. It is a clear, colourless, dense liquid, 1.62 times as heavy as water, with a mild sweetish odour, a boiling point of about 121 °C and a very low solubility in water of roughly 0.15 g/L. The pure compound is 85.5% chlorine by weight, which explains both its strong solvency and its resistance to burning.

The name “perchloroethylene” is the common industrial name; chemists write tetrachloroethylene or tetrachloroethene, and the trade shortens it to PCE or PERC. In Indonesia, dry-cleaning operators usually call it perkloroetilena or just perc. It should not be confused with trichloroethylene, which has three chlorine atoms and different solvent and hazard properties, or with hexachloroethane, a solid. On our quotations, CoAs and SDSs we identify the product as CAS 127-18-4 so that your incoming inspection matches what is in the drum.

Why it is used as a solvent

Perchloroethylene dissolves oils, fats, greases, waxes, resins and many organic materials more strongly than hydrocarbon solvents, yet it does not burn, has no flash point under normal conditions, and evaporates cleanly at moderate temperature. Its high density and low water solubility let it be separated from water easily, and it can be distilled and reused many times. Those properties are why it became the leading dry-cleaning solvent and a common fluid for vapour degreasing, where hot vapour condenses on cold parts and washes away oil.

Perchloroethylene compared with other solvents

Buyers choosing a cleaning or processing solvent usually compare it with chlorinated and hydrocarbon alternatives. Aromatic solvents such as toluene and ketones such as acetone dissolve many soils but are flammable, which changes plant and insurance requirements. Perchloroethylene is non-flammable but is heavier, more strongly regulated and needs closed machines with good vapour recovery. The choice depends on the soil, the part or fabric, the equipment and the compliance position of the site.

Grades we supply

We quote two grades. The dry-cleaning and industrial grade declares at least 99.5% purity with controlled water, acidity and residue, and is stabilised for use in machines and degreasers. The high-purity grade declares at least 99.9%, with tighter water, acidity, residue and colour limits, for chemical intermediate use, laboratory work and precision cleaning. The stabiliser package differs between producers, so we state it on the CoA and send samples before the first order.

A supplier, not a manufacturer

Chelora Chemicals is a sourcing and supply business. We buy perchloroethylene from vetted manufacturing partners, agree the specification with you before the purchase order, check each batch’s documents against it, and manage packing, dangerous goods paperwork and freight to your port or plant. We supply it as an industrial chemical for professional use, and we ask about the end use and your handling and permit arrangements before quoting.

02 / PHYSICAL & CHEMICAL PROPERTIES

Perchloroethylene properties: boiling point, density, solvency and vapour pressure

Typical values for commercial perchloroethylene, for orientation. The figures for your shipment are confirmed on the certificate of analysis and the SDS for that batch.

Physical PropertyTypical Value
Physical formClear, mobile liquid
Colour / odourColourless; mild, sweetish, ether-like odour
Molar mass165.82 g/mol
Densityabout 1.62 g/cm³ at 20 °C
Boiling pointabout 121 °C
Freezing pointabout −22 °C
Vapour pressureabout 1.7 – 2.5 kPa at 20 – 25 °C
Solubility in waterVery low, about 0.15 g/L; sinks below water
Chemical / Safety PropertyTypical Value
Flash pointNone under normal test conditions (non-flammable)
SolvencyDissolves oils, fats, greases, waxes and resins; mixes with most organic solvents
StabilityStable when stabilised and kept dry, cool and sealed
Thermal behaviourBreaks down in a flame or on very hot surfaces to hydrogen chloride, chlorine and phosgene
Incompatible materialsStrong bases, strong acids, strong oxidisers and reactive metals such as aluminium and magnesium powder
Hazardous decompositionHydrogen chloride, chlorine, carbon monoxide and carbon dioxide; phosgene in a fire
Vapour densityAbout 5.7 times air; vapour collects at floor level
Typical classificationH315, H317, H319, H336, H351, H411 (supplier SDSs)
03 / GRADE SPECIFICATION

Perchloroethylene specification: 99.5% and 99.9% grades, water, acidity and residue

Indicative limits for the two grades we quote. The binding specification is the one in your quotation and is confirmed on each certificate of analysis.

ParameterTest MethodDry-Cleaning / Industrial Grade (99.5%)High-Purity Grade (99.9%)
AppearanceVisualClear, colourless liquid, free of suspended matterClear, colourless liquid, free of suspended matter
Purity (C2Cl4)Gas chromatography≥ 99.5%≥ 99.9%
Density at 20 °CDensitometer1.620 – 1.626 g/cm³1.621 – 1.624 g/cm³
Colour (APHA)ASTM D1209 / Pt-Co≤ 15≤ 5
WaterKarl Fischer≤ 0.01%≤ 0.005%
Acidity (as HCl)Titration≤ 0.001%≤ 0.0005%
Alkalinity reserve (as NaOH)TitrationReported, by agreementReported, by agreement
Non-volatile residueGravimetric≤ 0.005%≤ 0.002%
StabiliserGC / titrationPresent, package stated on CoAAs agreed, or unstabilised on request
Distillation rangeASTM D1078120.5 – 121.5 °CReported
PackingVisualSteel drums, IBCs or ISO tanksSteel drums or IBCs

Limits are indicative. Dry-cleaning machine makers, degreasing equipment suppliers and chemical users often write their own limits for acidity, alkalinity reserve, water, residue and stabiliser content. Send us your specification and the test methods it names, and we confirm what our manufacturing partner can guarantee before you order.

04 / MANUFACTURING ROUTE

How perchloroethylene is made: high-temperature chlorination of ethylene-based feedstocks

An outline of the industrial routes, for orientation. Our manufacturing partners’ process conditions and in-process controls are proprietary and are shared only as far as needed to read the certificate of analysis.

Perchloroethylene is made mainly from the ethylene chain. One common route starts with 1,2-dichloroethane, produced from ethylene and chlorine, and heats it with more chlorine at about 400 °C, giving perchloroethylene and trichloroethylene together with hydrogen chloride. The overall reaction for the perchloroethylene path can be written C2H4Cl2 + 3 Cl2 → C2Cl4 + 4 HCl.

The other main route is chlorinolysis: light chlorinated hydrocarbons, including by-products from the vinyl chloride and chlorinated-solvent chain, are reacted with chlorine at high temperature, which breaks and rebuilds carbon bonds and yields perchloroethylene and carbon tetrachloride in proportions the producer can adjust. Hexachloroethane forms as an intermediate and cracks back to perchloroethylene and chlorine at the reaction temperature.

The crude product is washed and neutralised, then distilled to remove lighter and heavier chlorinated by-products. Stabilisers are added to the finished solvent, and it is filtered, tested and packed. The hydrogen chloride made along the way is recovered as hydrochloric acid or recycled, which is why perchloroethylene production is closely linked with the rest of the chlorine and vinyl chain.

05 / APPLICATIONS

Perchloroethylene uses in Indonesia: dry cleaning, metal degreasing, textile processing and chemical intermediates

Where industrial buyers use the solvent. Customers should confirm the handling, permit and waste requirements that apply to their own process with their regulatory adviser.

Field 01

Dry Cleaning (Dry Cleaning Pakaian)

In closed dry-cleaning machines the solvent lifts oils and soils from garments and fabrics without water, is filtered and distilled for reuse, and is recovered by condensation and carbon adsorption. Laundry chains and hotel and uniform services specify stabilised, low-acidity grades.

Field 02

Metal Degreasing (Pembersihan Logam)

Vapour degreasers and cold-cleaning tanks use it to remove oils, waxes, buffing compounds and cutting fluids from metal parts before plating, painting, bonding or assembly. Its non-flammable, high-boiling vapour suits hot vapour cleaning in closed equipment.

Field 03

Chemical Intermediate for Fluorocarbons

Perchloroethylene is a feedstock for some fluorinated products, such as chlorofluoroethanes and hydrofluorocarbon intermediates made by reaction with hydrogen fluoride. Intermediate users specify high purity and low water.

Field 04

Textile Processing & Fabric Finishing

Textile mills use chlorinated solvents to remove spinning oils, sizing residues and waxes from fibres and fabrics, and in some finishing and spot-cleaning steps. Centres in West and Central Java use it in specialised, closed processes.

Field 05

Adhesives, Cleaners & Solvent Blends

Formulators use it in solvent-based adhesives, stain and spot removers, aerosol cleaners and specialist degreasing blends, often with other solvents, where its non-flammable character and strong solvency are valued.

Field 06

Electronics & Precision Cleaning

High-purity grades clean electronic components, optics and precision parts where low residue, low water and low acidity matter. Electronics plants in Batam and Cikarang specify cleanliness limits in their own purchasing standards.

Field 07

Laboratory & Analytical Solvent

Spectroscopy, extraction and oil-in-water analysis laboratories use high-purity perchloroethylene as an extraction and infrared-transparent solvent, in small lots and with a batch certificate.

Field 08

Responsible Use & Regulatory Compliance

Perchloroethylene is a suspected carcinogen and an environmental pollutant, and its use is restricted in several countries. We supply it only for professional industrial use in suitable closed equipment, and ask buyers to confirm local permit, wastewater and waste requirements.

06 / REACTION CHEMISTRY

Perchloroethylene chemistry: chlorination, stabilisation, solvent action, decomposition and fluorination

Five points cover almost everything buyers need to understand about the solvent, from the reactor that makes it to the machine, tank or reactor that uses it.

Formation by Chlorination

C2H4Cl2 + 3 Cl2 → C2Cl4 + 4 HCl at about 400 °C. Further chlorination of the ethylene chain gives perchloroethylene, with hydrogen chloride as the by-product.

Stabilisation Against Breakdown

Heat, light, air, moisture and some metals can slowly break the solvent down to acids. Stabilisers neutralise acid and absorb radicals, which is why acidity and alkalinity reserve are specified.

Solvent Action

The molecule is non-polar and heavily chlorinated, so it dissolves oils, fats, waxes and resins. It does not dissolve inorganic salts or water, which is why soils and water separate cleanly from it.

Thermal & Chemical Decomposition

In a flame or on very hot surfaces it gives hydrogen chloride, chlorine and phosgene. Strong bases, reactive metals and unstabilised solvent can also drive breakdown, which is why welding and open flame must be kept away from vapour.

Conversion to Fluorocarbon Intermediates

With hydrogen fluoride over a catalyst, perchloroethylene can be converted stepwise into chlorofluoroethanes that serve as intermediates for hydrofluorocarbon products. This is a specialist industrial use.

07 / RELATED BUILDING BLOCKS

Perchloroethylene, other solvents and related products we supply

Buyers compare perchloroethylene with other chlorinated and organic solvents, buy the feedstocks and neutralising chemicals around it, or use it alongside cleaning solvents. This table sets out how each one relates to perchloroethylene.

ProductCAS NumberRelationship to PerchloroethyleneNotes
Perchloroethylene127-18-4This productNon-flammable chlorinated solvent, C2Cl4, in dry-cleaning and high-purity grades.
Mono Chlorobenzene108-90-7Chlorinated solventAromatic chlorinated solvent and intermediate; different boiling point and flammability.
Ortho Dichlorobenzene95-50-1Chlorinated solventHigh-boiling chlorinated solvent and intermediate for process and cleaning use.
Vinyl Chloride Monomer75-01-4Chlorinated chainMade from the same ethylene and chlorine chain that gives the chlorinated solvents.
Ethylene74-85-1Upstream feedstockStarting point of the ethylene dichloride route to perchloroethylene.
Hydrochloric Acid7647-01-0Process by-productHydrogen chloride from the chlorination is recovered as hydrochloric acid.
Caustic Soda1310-73-2Neutralising agentUsed to neutralise acidic residues and wash crude solvent; incompatible with the solvent itself.
Toluene108-88-3Alternative solventFlammable aromatic solvent used in blends and cleaning where flammability is acceptable.
Acetone67-64-1Alternative solventFast-evaporating, flammable cleaning solvent for light soils and equipment.
Methyl Ethyl Ketone78-93-3Alternative solventIndustrial ketone solvent for coatings, inks and adhesives.
N-Methyl-2-Pyrrolidone872-50-4Alternative cleaning solventPolar solvent used in electronics cleaning and paint stripping.

Exact physical constants and purity specifications are confirmed per batch on the certificate of analysis. For products other than Perchloroethylene, treat the notes above as a sourcing guide, not a specification sheet.

08 / HAZARD & HANDLING

Perchloroethylene hazards: GHS classification, vapour control and environmental protection

Based on typical supplier classifications for tetrachloroethylene. For orientation only: always work from the current SDS supplied with your batch.

H315 + H317

Causes skin irritation and may cause an allergic skin reaction. Repeated contact removes skin oils and dries the skin.

H319

Causes serious eye irritation. Splashes and strong vapour both irritate the eyes.

H336

May cause drowsiness or dizziness. Vapour at high concentration affects the nervous system; vapour is heavier than air and collects in low spots.

H351

Suspected of causing cancer (Carc. 2). Exposure should be kept as low as reasonably achievable under your EHS programme.

H411

Toxic to aquatic life with long-lasting effects (Aquatic Chronic 2); it sinks and persists in water.

Signal Word

Warning, with GHS07 (exclamation mark), GHS08 (health hazard) and GHS09 (environment) pictograms.

P201 + P202 + P261

Obtain special instructions before use, do not handle until safety precautions are read, and avoid breathing vapour.

P273 + P391

Avoid release to the environment and collect spillage before it reaches drains, rivers or soil.

Vapour Control

Use closed machines, local exhaust at filling and open tanks, floor-level ventilation and vapour monitoring where operators work.

PPE Standard

Chemical-resistant gloves rated for chlorinated solvents (such as Viton or PVA; nitrile and latex degrade quickly), splash goggles, coveralls and respiratory protection per the SDS.

First Aid

Move to fresh air after inhalation; flush eyes and skin with water; do not induce vomiting if swallowed. Get medical attention and show the SDS.

Transport

UN 1897, tetrachloroethylene, Class 6.1, PG III, marine pollutant, as confirmed in Section 14 of the batch SDS.

Typical supplier safety data sheets list tetrachloroethylene as Skin Irrit. 2 (H315), Skin Sens. 1 (H317), Eye Irrit. 2 (H319), STOT SE 3 (H336), Carc. 2 (H351) and Aquatic Chronic 2 (H411), signal word Warning, under EU index number 602-028-00-4; the exact set can differ between sources, which is why the SDS for your batch is the reference. The EU indicative occupational exposure limit is 20 ppm (138 mg/m³) as an 8-hour average and 40 ppm (275 mg/m³) for 15 minutes, with a skin notation; other countries set their own limits, and you should confirm the applicable limit for your site. The practical risks are vapour at operator level, skin contact, and release to drains or soil: the solvent is denser than water and persists, so bunding, closed transfer and proper waste handling matter. It does not burn, but it breaks down in a flame or on very hot surfaces to hydrogen chloride, chlorine and phosgene, so keep welding, grinding and open flame away. Read the full SDS before handling.

09 / STORAGE & SHELF LIFE

Storing perchloroethylene sealed, cool and bunded in Indonesia

General storage guidance for the liquid. Your own EHS procedures and the batch SDS set the site-specific rules, segregation and re-test intervals.

Storage ConditionCool, shaded, ventilated store with bunded impermeable floor
ContainerOriginal sealed steel drums, IBCs or approved tanks
Typical Shelf Life2 years from manufacture, sealed and stabilised
Keep Away FromStrong bases, strong acids, reactive metals, heat, flame and food
Beyond Retest DateRe-test acidity, water, stabiliser and colour

Stabilised perchloroethylene is stable at ordinary temperatures, but heat, sunlight, moisture and contact with reactive metals can start slow breakdown and raise acidity. In Indonesian warehouses, where roof sheets and drums can get hot, keep drums in the shade, off the floor and away from walls that heat up in the sun, with bungs tight so that moisture and vapour do not move in or out. Because the liquid is heavier than water and persistent, put drums on a bunded floor with a sump so leaks can be recovered, keep drains covered, and never store it near open drains or watercourses. Segregate it from strong bases, strong acids and powdered metals, and from food and feed. Vent and ventilate stores at low level, since vapour sinks. Use stock first in, first out, and re-test acidity, water, stabiliser and colour on lots past their retest date; a rising acidity reading is the first sign that the solvent needs attention.

10 / PACKING & SHIPPING

Perchloroethylene packing: steel drums, IBCs and ISO tanks

Standard packing and shipping terms for the liquid. Exact figures depend on origin, destination port and quantity and are confirmed with your order.

Standard PackingSteel drums, about 300 – 320 kg net200 L closed-head steel drums, UN-marked, palletised and strapped
Bulk PackingIBC, about 1,500 – 1,600 kgUN-approved IBCs for plants with transfer pumps and secondary containment
Tank PackingISO tank, about 20 – 24 tonnesfor large dry-cleaning, degreasing or chemical users, with road delivery
Min. OrderFrom 1 tonne in drumslarger lots for IBCs and ISO tanks; samples on request
Lead Time3 – 5 weeks bulkfrom order confirmation, plus transit
Shipment TypeTypical LoadBest ForNotes
LCL (part container)1 – 8 tonnesDry-cleaning chains, small plants, trial lotsMoves as dangerous goods, so only DG-accepting consolidators can take it; book early.
20′ FCL, steel drumsAbout 16 – 22 tonnesDistributors, degreasing and textile usersPalletised drums; load depends on drum fill and pallet configuration.
20′ FCL, IBCsAbout 14 – 20 tonnesPlants with IBC pumping stationsFewer packs to handle; weight limits and secondary containment decide the load.
ISO tankAbout 20 – 24 tonnesLarge chemical and solvent-blending usersNeeds a suitably licensed tank terminal and receiving point; confirm the unloading arrangement before booking.
Call-off contractsMonthly or quarterly lotsDry-cleaning and degreasing users needing one consistent gradeAgreed specification and schedule; lots kept from the same manufacturing partner where possible.
11 / SUPPLY ACROSS INDONESIA

Perchloroethylene supplier in Indonesia

Pengiriman ke seluruh Indonesia — delivery throughout Indonesia. We ship perkloroetilena to dry-cleaning, metal-finishing, textile and chemical plants through the nearest major port, with onward trucking or inter-island shipping to your site.

Indonesian demand for perchloroethylene comes from a few specialised user groups. Dry-cleaning chains, hotel and uniform laundries, and garment service companies in Jakarta, Bekasi, Tangerang, Surabaya and Bandung use it in closed dry-cleaning machines, while metal-finishing, automotive-component and machinery plants around Cikarang, Karawang, Surabaya and Gresik use it for vapour and cold degreasing before plating and painting.

Textile mills and processors in Bandung, Majalaya, Solo and Semarang use it as a processing solvent, chemical and solvent-blend makers around Cilegon and Jakarta use it as an intermediate and as a blend component, and electronics plants in Batam and Cikarang buy high-purity grades for precision cleaning. Shipments land at Tanjung Priok, Tanjung Perak, Tanjung Emas or Batu Ampar for most buyers, or at Belawan and other regional ports, in closed containers or ISO tanks with DG-licensed carriers. Our desk works in English and can share quotations, CoA summaries and delivery updates in Bahasa Indonesia for your purchasing and technical staff on request.

RegionKey Cities & Industrial EstatesPort of DeliveryTypical Buyers
DKI JakartaJakarta, Pulogadung (JIEP), Marunda, CakungTanjung PriokDry-cleaning chains, hotel and uniform laundries, chemical traders
BantenCilegon (KIEC), Serang, Cikande, Tangerang, BalarajaMerak / Ciwandan · Tanjung PriokChemical and solvent-blend makers, textile and metal-finishing plants
West JavaBekasi, Cikarang (Jababeka, MM2100, EJIP, Delta Silicon), Karawang (KIIC, Suryacipta), Purwakarta, BandungTanjung Priok · PatimbanAutomotive and component degreasing, textile mills, dry-cleaning operators
Central JavaSemarang (Wijayakusuma), Kendal Industrial Park, Batang, SoloTanjung EmasTextile processors and garment plants, metal-finishing plants
East JavaSurabaya (SIER), Gresik (JIIPE), Sidoarjo, Pasuruan (PIER), Mojokerto (Ngoro)Tanjung PerakDry-cleaning chains, metal-finishing and machinery plants, chemical distributors
Riau IslandsBatam (Batamindo, Kabil), BintanBatu Ampar (Batam)Electronics and precision-cleaning users
North SumatraMedan (KIM), Kuala Tanjung, Sei MangkeiBelawan · Kuala TanjungDry-cleaning operators, metal workshops and chemical distributors
Riau & South SumatraDumai, Pekanbaru, PalembangDumai · Boom Baru (Palembang)Equipment-maintenance and oil-service cleaning users, chemical distributors
LampungBandar Lampung, Tanjung BintangPanjangChemical distributors and regional workshops
KalimantanBalikpapan (Kariangau), Bontang, Samarinda, Banjarmasin, PontianakSemayang · Trisakti · PontianakEquipment-maintenance and process-cleaning users, laundries
SulawesiMakassar (KIMA), Bitung, MorowaliMakassar New Port · BitungRegional chemical distributors, dry-cleaning operators
Import 01

HS Code & Customs

Perchloroethylene is classified under HS 2903.23, tetrachloroethylene, within heading 29.03 (halogenated derivatives of hydrocarbons). Your PPJK broker confirms the national subheading, the invoice, packing list, CoA and SDS are drawn up to match, and an ATIGA Form D is issued where the origin qualifies.

Import 02

Dangerous Goods & SDS

Shipped as UN 1897, tetrachloroethylene, Class 6.1, PG III, marine pollutant, with a DG declaration, hazard labels on each pack, container placards and a GHS-format SDS. We work with your forwarder or PPJK broker on any hazardous-substance handling requirements at your end.

Import 03

Industrial Supply & Regulatory Checks

We supply the solvent as an industrial raw material for professional use in suitable closed equipment. Several countries restrict this solvent, and we have not verified an Indonesian listing here, so please confirm permit, wastewater and waste requirements for your site; we ask about the end use before quoting.

Import 04

Delivery to Industrial & Laundry Centres

Java plants are served through Tanjung Priok, Tanjung Emas or Tanjung Perak; Batam direct through Batu Ampar; Sumatra and Kalimantan users direct or by transhipment, in closed containers or ISO tanks with DG-licensed carriers.

Delivery Cities in Indonesia

JakartaTangerangCilegonSerangBekasiCikarangKarawangPurwakartaBandungSemarangKendalSoloSurabayaGresikSidoarjoPasuruanMojokertoBatamBintanMedanDumaiPekanbaruPalembangBandar LampungBalikpapanBontangSamarindaBanjarmasinPontianakMakassarBitung
12 / QUALITY & DOCUMENTATION

What travels with every batch

The specification is agreed before the purchase order, not discovered on arrival. Every shipment of perchloroethylene leaves with a documented, checkable paper trail.

Doc 01

Certificate of Analysis

Batch-wise purity, density, colour, water, acidity, non-volatile residue and stabiliser, with manufacturing date, issued against the agreed specification so your QC team can check it rather than just file it.

Doc 02

Safety Data Sheet

GHS-format SDS in English covering hazard classification, handling, storage, first aid and spill response for the exact grade shipped.

Doc 03

Technical Data Sheet

Reference properties, specification, recommended storage and typical uses, plus stabiliser and material-compatibility statements your technical team can request.

Doc 04

Certificate of Origin

States the country of manufacture for customs clearance and any preferential-duty claim at your Indonesian port of discharge.

Doc 05

Dangerous Goods Declaration

UN number, class and packing group as stated in Section 14 of the batch SDS: the DG declaration and container packing certificate are prepared before loading so documentation never holds up the vessel or customs.

Doc 06

Third-Party Inspection

Independent pre-shipment inspection and re-sampling can be arranged on request, at your cost, for buyers whose policy requires it.

13 / HOW ORDERING WORKS

From enquiry to delivery

A typical first order for perchloroethylene, whether it is going to Jakarta, Cikarang, Bandung, Surabaya or Batam.

Enquiry

Send grade, specification, quantity, packing, destination port or plant and your end use. The end use tells us which limits matter and what handling and permit arrangements your site needs.

Quotation

Most enquiries are quoted within one working day, with specification, price basis, Incoterm, lead time and payment terms in writing.

Sample & Specification Sign-off

Pre-shipment samples and a typical CoA can be sent so your QC team can test the solvent in your own machine or process and approve the grade before you commit to volume.

Purchase Order & Booking

Once the PO is confirmed we book DG container or tank space, prepare labels and paperwork, and share the vessel schedule.

Dispatch & Documents

Bill of lading, commercial invoice, packing list, CoA, SDS, DG declaration and certificate of origin are sent ahead of arrival.

Delivery & After-Sales

We track the shipment to your port or plant and handle any documentation or quality queries after arrival.

14 / FAQ

Perchloroethylene FAQs: CAS number, dry cleaning, degreasing, hazards, packing and price

What industrial buyers in Indonesia most often ask our sales desk about perchloroethylene.

01What is perchloroethylene and what is it used for?+
Perchloroethylene, also called PCE, PERC or tetrachloroethylene, is a clear, colourless, non-flammable chlorinated solvent with the formula C2Cl4. It is used mainly as a dry-cleaning solvent, for vapour and cold degreasing of metal parts, in textile processing, in solvent blends for adhesives, cleaners and aerosols, and as a chemical intermediate for fluorocarbons. We supply it to industrial buyers across Indonesia.
02What are the CAS number, EC number, HS code and UN number of perchloroethylene?+
CAS 127-18-4, EC 204-825-9 and EU index number 602-028-00-4, registered as tetrachloroethylene. It is classified under HS 2903.23 (tetrachloroethylene), with the national subheading confirmed by your customs broker. For transport it is UN 1897, tetrachloroethylene, Class 6.1, PG III, marine pollutant, as confirmed in Section 14 of the SDS for your batch.
03Is perchloroethylene the same as tetrachloroethylene, PCE and perkloroetilena?+
Yes. Perchloroethylene, tetrachloroethylene, tetrachloroethene, PCE and PERC are the same compound, CAS 127-18-4. Perkloroetilena and tetrakloroetilena are descriptive Indonesian renderings rather than fixed trade terms. It should not be confused with trichloroethylene (C2HCl3), a different solvent, or with hexachloroethane (C2Cl6).
04What grades of perchloroethylene do you supply?+
We quote a dry-cleaning and industrial grade at 99.5% minimum and a high-purity grade at 99.9% minimum, both usually stabilised, with water, acidity, non-volatile residue and colour reported on the certificate of analysis. The stabiliser package matters for dry-cleaning machines and for metal degreasing, so tell us your equipment and process and we confirm what our manufacturing partner can supply.
05Why is perchloroethylene stabilised?+
Chlorinated solvents can slowly break down in the presence of heat, light, air, moisture and some metals, forming hydrochloric acid and other acidic products that attack equipment and can damage the work. Small amounts of stabiliser neutralise acid and absorb radicals, keeping acidity and corrosion low. Stabiliser content should be checked on arrival, and acid readings in a still or machine are a warning to inspect it.
06How is perchloroethylene used in dry cleaning and metal degreasing?+
In dry cleaning, the solvent dissolves oils and soils from garments in a closed machine, is filtered and distilled for reuse, and is recovered by condensation and carbon adsorption. In degreasing it is used in vapour-phase or cold-cleaning equipment to remove oils, waxes and cutting fluids from metal parts before plating, painting or assembly. Because it is not flammable and boils at 121 degrees Celsius, it suits hot vapour cleaning, but it needs tight vapour control.
07What are the main hazards of perchloroethylene?+
Typical supplier safety data sheets list skin irritation (H315), possible skin allergy (H317), serious eye irritation (H319), drowsiness or dizziness from vapour (H336), suspected cancer (H351) and toxic effects on aquatic life with long-lasting effects (H411), with the signal word Warning. Vapour is heavier than air, so ventilation at floor level and closed handling matter. The SDS for your batch is the reference.
08What exposure limits apply to perchloroethylene?+
The EU indicative occupational exposure limit is 20 ppm (138 mg/m3) as an 8-hour average and 40 ppm (275 mg/m3) for 15 minutes, with a skin notation, and other countries set their own values. We cannot state an Indonesian limit as verified here, so please confirm the applicable workplace limit and permit requirements with your EHS or regulatory adviser before use.
09How should perchloroethylene be stored in Indonesia?+
Keep it in its original sealed steel drums or approved tanks in a cool, shaded, well-ventilated store with a bunded, impermeable floor, away from direct sun and heat. Keep it away from strong bases, strong acids, reactive metals such as aluminium and magnesium powders, and from food and feed. Reseal part-used drums at once, use stock first in, first out, and check acidity and stabiliser on lots past their retest date.
10How is perchloroethylene packed and shipped?+
Standard packing is steel drums of about 300 to 320 kg net, with IBCs and ISO tanks for larger users, in closed containers with dangerous goods paperwork. It ships as UN 1897, Class 6.1, PG III, marine pollutant, so it needs DG-accepting carriers and labelled packs. Orders start from about one tonne in drums, and bulk lead time is typically three to five weeks plus transit.
11What is the price of perchloroethylene in Indonesia?+
The price depends on grade, stabiliser package, packing, quantity, origin, delivery point and freight and feedstock costs at the time of order. Send us your required grade, volume, packing and delivery location through the contact page and we will quote CFR, CIF or DAP in writing, usually within one working day, with the specification stated so offers can be compared.
12Can I get a sample and a certificate of analysis?+
Yes. Pre-shipment samples with a typical certificate of analysis can be arranged so your technical team can test the solvent in your own machine or process before committing to volume. Each shipment carries a batch CoA, SDS, DG declaration and certificate of origin. Samples of solvents also move as dangerous goods, so allow time for the paperwork.
13Are there restrictions on using perchloroethylene in Indonesia?+
Perchloroethylene is a suspected carcinogen and an environmental pollutant, and several countries restrict or phase down its use, particularly in dry cleaning. We have not verified an Indonesian listing or limit here, so please confirm hazardous-substance, permit, wastewater and waste-handling requirements for your site with your regulatory adviser. We ask about the end use before quoting.
14What chemicals should perchloroethylene not be mixed with?+
Avoid strong bases, strong acids, reactive metals such as powdered aluminium and magnesium, and strong oxidisers. Heat, flame or hot surfaces can break it down into hydrogen chloride, chlorine and phosgene, so never weld, grind or use open flame near the solvent or its vapour. Unstabilised solvent in contact with aluminium can react, which is why the stabiliser package matters.
Request This Grade · Minta Penawaran

Buy perchloroethylene in Indonesia: stabilised C2Cl4 solvent, on spec and on time

Send us your required grade, quantity, packing preference, end use and port or plant location anywhere in Indonesia. Our desk quotes most enquiries within one working day.